Panic Exit Device Mounting Height
Code publications define panic hardware as a door latching assembly incorporating a device that releases the latch upon the application of a force.
Panic exit device mounting height. The low limit for existing hardware is not specifically called out in the newer editions of nfpa 101 and older editions of nfpa 101 only included a maximum mounting height of 48 aff as well. There are some internal parts that may be different and the method it is secured to the d. The ontario building code door release hardware 3 4 6 16. Door hardware mounting heights 2010 ada changes.
Measure a maximum height of 46 inches above the floor for a panic device on a wall behind a desk or cabinet having a maximum depth of 24 inches and a maximum height of 34 inches. The most obvious difference in the device is the lack of mechanical dogging on a fire rated device. Although fact that a minimum mounting height for panic devices may be 36 most all commercial hardware is installed at 41 to the center of the push bars. Rim panic mounting height.
Von duprin 6300 electric strike will operate with 88 rim but not 88f fire rated exit devices. Panic hardware is an exit device which is tested for u. Rim panic device. Clear the space in front of the panic device at all times.
Why do the mounting studs on the 379l not line up with the back of the 55 rim. Door handles pulls latches locks and other operating devices shall be installed 34 inches 864 mm minimum and 48 inches 1219 mm maximum above the finished floor. Paint or install a clear space marking on the floor that is 48 inches square to permit disabled access to the panic device. Panic hardware mounting height.
Any other height would cause the top rod or bottom rod to be short or too long. Measure a maximum height of 46 inches above the floor for a panic device on a wall behind a desk or cabinet having a maximum depth of 24 inches and a maximum height of 34 inches. Panic hardware also known as an exit device or fire exit hardware when used on fire doors is designed to provide fast and easy egress to allow building occupants to exit safely in an emergency. Choose a different location if the cabinet obstruction exceeds these maximum dimensions.
Panic hardware also known as an exit device is designed to provide building occupants fast and easy egress in an emergency. Panic hardware may be mounted between 30 and 48 aff and the releasing mechanism for other latching hardware may be mounted below 48 aff.